Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Braz. dent. sci ; 26(1): 1-9, 2023. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1411424

ABSTRACT

Objective: Evaluate the mechanical properties of experimental adhesive models with different photoinitiators (PI) polymerized by LED units of different power densities. Material and Methods: Three groups of adhesive models based on HEMA/BisGMA (45/55) were prepared in association with different PI combinations: G2 (control) ­ 2 PI: 0.5% CQ, 0.5% EDMAB; G3 - 3 PI: 0.5% CQ; 0.5% DMAEMA, 0.5% DPIHP; G4 - 4 PI: 0.5% CQ; 0.5% EDMAB; 0.5% DMAEMA; 0.5% DPIHP. The three formulations were polymerized at two different LED power densities: 550 mW/cm2 and 1200 mW/cm2. The degree of conversion (DC) of adhesive monomers was monitored in situ through the FTIR for 600 s. Specimens were prepared for each formulation for analysis mong adhesive systems (G2

Objetivo: Avaliar as propriedades mecânicas de modelos adesivos experimentais com diferentes fotoiniciadores (PI) polimerizados por unidades de LED de diferentes densidades de energia. Material e Métodos: Três grupos de modelos adesivos baseados em HEMA/BisGMA (45/55) foram preparados em associação com diferentes combinações de PI: G2 (controle) ­ 2 PI: 0,5% CQ, 0,5% EDMAB; G3 - 3PI: 0,5% CQ; 0,5% DMAEMA, 0,5% DPIHP; G4 - 4 PI: 0,5% CQ; 0,5% EDMAB; 0,5% DMAEMA; 0,5% DPIHP. As três formulações foram polimerizadas em duas densidades de potência de LED: 550 mW/cm2 e 1200 mW/cm2. O grau de conversão (DC) dos monômeros adesivos foi monitorado in situ através do FTIR durante 600 s. Amostras foram preparadas para cada formulação para análise de resistência à flexão (FS), módulo de elasticidade (ME), sorção (SOR) e solubilidade (SOL). Os dados foram submetidos aos testes ANOVA 2-fatores e Tukey (5%). Resultados: DC: houve diferença significativa entre os sistemas adesivos (G2

Subject(s)
Radiation , Dentin-Bonding Agents , Light-Curing of Dental Adhesives , Photoinitiators, Dental
2.
Braz. arch. biol. technol ; 64(spe): e21210131, 2021. tab, graf
Article in English | LILACS | ID: biblio-1285563

ABSTRACT

Abstract The growth in the use of solar energy has encouraged the development of techniques for short-term prediction of solar photovoltaic energy generation (PSPEG). Machine learning with Artificial Neural Networks (ANNs) is the most widely used technique to solve this problem. However, comparative studies of these networks with distinct structural configurations, input parameters and prediction horizon, have not been observed in the literature. In this context, the aim of this study is to evaluate the prediction accuracy of the Global Horizontal Irradiance (GHI), which is often used in the PSPEG, generated by ANN models with different construction structures, sets of input meteorological variables and in three short-term prediction horizons, considering a unique database. The analyses were performed with controlled environment and experimental configuration. The results suggest that ANNs using the input GHI variable provide better accuracy (approximately 10%), and their absence increases error variability. No significant difference (p>0.05) was identified in the prediction error models trained with distinct meteorological input data sets. The prediction errors were similar for the same ANN model in the different prediction horizons, and ANNs with 30 and 60 neurons with one hidden layer demonstrated similar or higher accuracy than those with two hidden layers.


Subject(s)
Solar Energy , Neural Networks, Computer , Solar Radiation , Photovoltaic Energy
3.
Indian J Ophthalmol ; 2019 Oct; 67(10): 1624-1627
Article | IMSEAR | ID: sea-197524

ABSTRACT

Purpose: To evaluate light exposure from microscope versus intracameral illuminations to patient's and surgeon's retina during cataract surgery. Methods: Thirty consecutive patients who had cataract surgery using microscope and intracameral illuminations. At the point of the ocular of an operating microscope, optical illuminance and irradiance from the microscope illumination (60, 40, 20% intensity) and the intracameral illumination (60% intensity) were measured using a light meter and a spectrometer at a pause after lens capsule polishing in cataract surgery. Results: Average illuminance (lux) was 1.46, 0.66, 0.27, and 0.1 from 60%, 40%, 20% intensity microscope illuminations and 60% intracameral illumination. Average total spectral irradiance (?W/cm2) was 1.25, 0.65, 0.26, and 0.03 from 60%, 40%, 20% intensity microscope illuminations and 60% intracameral illumination. Conclusion: Microscope ocular illuminance and irradiance during cataract surgery were higher in the microscope illumination than in the intracameral illumination. It suggests that light exposure reaching patient's and surgeon's retina during cataract surgery is lower in the intracameral illumination than in the microscope illumination.

4.
Indian J Dermatol Venereol Leprol ; 2019 Sep; 85(5): 462-465
Article | IMSEAR | ID: sea-192518

ABSTRACT

Background: Psoralen with ultraviolet A is an effective photochemotherapeutic modality. A subtype of this, PUVAsol, uses sunlight as the natural source of ultraviolet A. The amount of sunlight received and the consequent ultraviolet A exposure vary according to the month in the year, time of the day and geographical location of a place. Aim: The aim of this study is to determine irradiance of ultraviolet A in ambient sunlight and optimum exposure time for PUVAsol. Materials and Methods: This was an observational study carried out at Postgraduate Institute of Medical Education and Research, Chandigarh (30.7333°N, 76.7794°E), India using a photometer. Ultraviolet A irradiance was recorded at a fixed place at 10 AM, once weekly for a period of 12 months. Results: The irradiance of peak ultraviolet A was found to be 3.1 mW/cm2 in June 2016 while irradiance of 0.64 mW/cm2 was recorded in January 2017. The exposure time needed for therapeutic dose of 2 J/cm2 was 11 min 6 s in June 2016 while exposure time for achieving therapeutic dose of 2 J/cm2 was 52 min 5 s in January 2017. The duration of exposure was found to be significantly longer in the winter months. Limitation: The limitation of the study is not determining ultraviolet B radiation and infrared exposure. Other limitation of this study is that the irradiance was measured only at 10 am. This data cannot be used to determine irradiance at different time points in the day as the patient may expose himself/herself to sunlight anytime depending on his/her convenience. Conclusions: The study demonstrates the mean exposure time required for a given therapeutic dose of ultraviolet A in different months. The wide variation in ultraviolet A irradiance in natural sunlight over the year in different months also suggests that exposure times for PUVAsol should be based on the season and geographical location at the site of therapy and not based on uniform guidelines.

5.
Braz. dent. j ; 30(4): 397-403, July-Aug. 2019. tab, graf
Article in English | LILACS | ID: biblio-1011558

ABSTRACT

Abstract This study measured and compared exitance irradiance and power of 4 commercial dental light-curing units (LCU) (Elipar S10, Elipar DeepCure-S, Corded VALO and Bluephase Style) using different types of radiometers. The devices used to analyze the LCU were classified as either handheld analog (Henry Schein, Spring, Demetron 100A, Demetron 100B and Demetron 200), handheld digital (Bluephase 1, Bluephase II, Coltolux, CureRite and Hilux), or laboratory instruments (Thermopile and Integrating Sphere). The laboratory instruments and the Bluephase II radiometer were also used to measure the LCU's power (mW). The LCU's were activated for 20 s (n=5). Data were analyzed using Kruskal-Wallis and Student-Newman-Keuls multiple comparison test (a=0.05). Among the LCU, the laboratory instruments presented different irradiance values, except for Corded VALO. The Coltolux and Hilux radiometers measured greater irradiance values compared to the laboratory instruments for the four LCUs tested. Within a given LCU, handheld analog units measured lower irradiance values, compared to handheld digital and laboratory instruments, except using the Spring radiometer for the Elipar S10 LCU. None of the handheld radiometers were able to measure similar irradiance values compared to laboratory instruments, except for Elipar S10 when comparing Bluephase 1 and Thermopile. Regarding power measurement, Bluephase II always presented the lowest values compared to the laboratory instruments. These findings suggest that the handheld radiometers utilized by practitioners (analog or digital) exhibit a wide range of irradiance values and may show lower outcomes compared to laboratory based instruments.


Resumo Esse estudo mensurou e comparou a irradiância e a energia de quatro fotopolimerizadores comerciais (Elipar S10, Elipar DeepCure-S, Corded VALO e Bluephase Style) utilizando diferentes tipos de radiômetros. Os dispositivos utilizados para analisar os fotopolimerizadores foram classificados em portáteis analógicos (Henry Schein, Spring, Demetron 100A, Demetron 100B e Demetron 200), portáteis digitais (Bluephase 1, Bluephase II, Coltolux, CureRite e Hilux), ou instrumentos laboratoriais (Thermopile e Integrating Sphere). Os instrumentos laboratoriais e o radiômetro Bluephase II também foram utilizados para medir a energia dos fotopolimerizadores (mW). Os fotopolimerizadores foram ativados por 20 s (n=5). Os dados foram analisados utilizando Kruskal-Wallis e teste de Student-Newman-Keuls (a=0,05). Dentre os fotopolimerizadores, os instrumentos laboratoriais apresentaram diferentes valores de irradiância, exceto para o Corded VALO. O Coltolux e o Hilux mensuraram uma irradiância maior comparado aos instrumentos de laboratório para os quatro fotopolimerizadores testados. Para o mesmo fotopolimerizador, os radiômetros analógicos portáteis mensuraram menores valores de irradiância quando comparados aos digitais portáteis ou aos instrumentos laboratoriais, exceto quando utilizado o Spring para o Elipar S10. Nenhuma diferença foi observada entre os instrumentos laboratoriais na irradiância do Corded VALO. Para a medição da energia, nenhuma diferença foi observada usando Thermopile e a Integrating Sphere para o Corded VALO. Para os outros fotopolimerizadores, cada instrumento indicou uma energia diferente. Esses achados sugerem que radiômetros portáteis utilizados pelos cirurgiões-dentistas (analógico ou digital) exibem uma ampla gama de valores de irradiância e podem mostrar medidas inferiores comparados aos instrumentos de laboratório.


Subject(s)
Humans , Radiometry , Curing Lights, Dental , Materials Testing , Composite Resins
6.
Braz. dent. j ; 28(3): 362-371, May-June 2017. tab, graf
Article in English | LILACS | ID: biblio-888649

ABSTRACT

Abstract This study measured the radiant power (mW), irradiance (mW/cm2) and emission spectra (mW/cm2/nm) of 22 new, or almost new, light curing units (LCUs): - Alt Lux II, BioLux Standard, Bluephase G2, Curing Light XL 3000, Demetron LC, DX Turbo LED 1200, EC450, EC500, Emitter C, Emitter D, KON-LUX, LED 3M ESPE, Led Lux II, Optilight Color, Optilight Max, Optilux 501, Poly Wireless, Radii cal, Radii plus, TL-01, VALO Cordless. These LCUs were either monowave or multiple peak light emitting diode (LED) units or quartz-tungsten-halogen LCUs used in anterior and posterior teeth. The radiant power emitted by the LCUs was measured by a laboratory grade laser power meter. The tip area (cm²) of the LCUs was measured and used to calculate the irradiance from the measured radiant power source. The MARC-Patient Simulator (MARC-PS) with a laboratory grade spectrometer (USB4000, Ocean Optics) was used to measure the irradiance and emission spectrum from each LCU three times at the sensor located on the facial of the maxillary central incisors and then separately at the occlusal of a maxillary second molar. The minimum acceptable irradiance level was set as 500 mW/cm2. Irradiance data was analyzed using two-way ANOVA and the radiant power data was analyzed by one-way ANOVA followed by Tukey test (a=0.05). In general, the irradiance was reduced at the molar tooth for most LCUs. Only the Valo, Bluephase G2 and Radii Plus delivered an irradiance similar to the anterior and posterior sensors greater than 500 mW/cm2. KON-LUX, Altlux II, Biolux Standard, TL-01, Optilux 501, DX Turbo LED 1200 LCUs delivered lower irradiance values than the recommended one used in molar region, KON-LUX and Altlux II LCUs used at the maxillary incisors. Bluephase G2 and Optilight Max delivered the highest radiant power and KON-LUX, Altlux II and Biolux Standard delivered the lowest power. The emission spectrum from the various monowave LED LCUs varied greatly. The multi-peak LCUs delivered similar emission spectra to both sensors.


Resumo Este estudo mediu a potência (mW), irradiância (mW/cm2) e espectro da luz (mW/cm2/nm) emitida por 22 fontes de luz (Alt Lux II, BioLux Standard, Bluephase G2, Curing Light XL 3000, Demetron LC, DX Turbo LED 1200, EC450, EC500, Emitter C, Emitter D, KON-LUX, LED 3M ESPE, Led Lux II, Optilight Color, Optilight Max, Optilux 501, Poly Wireless, Radii cal, Radii plus, TL-01, VALO Cordless) disponíveis comercialmente. A potência emitida pelas fontes de luz foi medida usando um medidor laboratorial de potencia com grade a laser. A área (cm²) da ponta ativa efetiva das fontes de luz foi medida com paquímetro digital e utilizada para calcular a irradiância emitida. O simulador de paciente-MARC (MARC - PS) com espectrómetro (USB4000, Ocean Optics) foi usado para medir a irradiância e o espectro de luz emitida por cada fonte de luz na região anterior e posterior. Esta medição foi repetida por três vezes em dois sensores localizados na região anterior e posterior da arcada dentária. Os dados de irradiância foram analisados utilizando análise de variância em dois fatores, e os dados de potência foram analisados com análise de variância em fator único seguido pelo teste de Tukey (a=0,05). As fontes de luz Valo, Bluephase G2, Radii Plus emitiram irradiância semelhante tanto na região anterior como posterior com valores superiores ao mínimo de 500 mW/cm2. Seis fontes de luz emitiram irradiância menor que o recomendado (500 mW/cm2) quando usadas na região posterior: Kon-lux, Altlux II, Biolux Standard TL-01, Optilux 501, DX Turbo LED 1200 e duas quando usadas na região anterior: Kon-lux e Altlux II LCUs. As fontes Bluephase G2, Optilight Max emitiram os maiores valores de potência e as fontes de luz Altlux II e Biolux Standard emitiram os menores valores de potência. O espectro de luz das fontes LED de espectro único variou de forma evidente entre as fontes. As fontes LED multi pico de espectro emitiram espectros de luz similar para ambos os sensores. A fotoativação na região posterior tende a reduzir substancialmente a irradiância da maioria das fontes de luzes testadas.


Subject(s)
Humans , Curing Lights, Dental , Dental Restoration, Permanent , Lasers , Patient Simulation , Spectrum Analysis/instrumentation , Tooth/radiation effects
7.
Braz. dent. j ; 28(1): 9-15, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-839109

ABSTRACT

Abstract The high irradiance and the different emission spectra from contemporary light curing units (LCU) may cause ocular damage. This study evaluated the ability of 15 eye protection filters: 2 glasses, 1 paddle design, and 12 dedicated filters to block out harmful light from a monowave (HP-3M ESPE) and a broad-spectrum (Valo, Ultradent) LED LCU. Using the anterior sensor in the MARC-Patient Simulator (BlueLight Analytics) the irradiance that was delivered through different eye protection filters was measured three times. The LCUs delivered a similar irradiance to the top of the filter. The mean values of the light that passed through the filters as percent of the original irradiance were analyzed using two-way ANOVA followed by Tukey test (a= 0.05). The emission spectra from the LCUs and through the filters were also obtained. Two-way ANOVA showed that the interaction between protective filters and LCUs significantly influenced the amount of light transmitted (p< 0.001). Tukey test showed that the amount of light transmitted through the protective filters when using the HP-3M-ESPE was significantly greater compared to when using the Valo, irrespective of the protective filter tested. When using the HP-3M-ESPE, the Glasses filter allowed significantly more light through, followed by XL 3000, ORTUS, Google Professional, Gnatus filters. The Valo filter was the most effective at blocking out the harmful light. Some protective filters were less effective at blocking the lower wavelengths of light (<420 nm). However, even in the worst scenario, the filters were able to block at least 97% of the irradiance.


Resumo A alta irradiância e diferentes espectros de luz emitidos por aparelhos fotopolimerizadores (Fp) podem causar danos oculares. Este estudo avaliou a capacidade de 15 filtros de proteção ocular em bloquear a luz prejudicial de um Fp convencional (HP-3M ESPE) e outro de largo espectro (Valo, Ultradent). Utilizando sensor anterior do equioamento MARC-Patient Simulator (BlueLight Analytics inc.) a irradiância que passou através dos diferentes filtros protetores foi mensuradas três vezes. Os valores médios da irradiância que passaram pelos filtros foram analisados usando Análise de variância fatorial e pelo teste de Tukey (a= 0.05). O espetro emitido dos Fps através dos filtros também foi obtido. A análise de variância mostrou que a interação entre os filtros protetores e Fps influenciou significantemente a quantidade de luz transmitida (p<0,001). O teste de Tukey mostrou que a quantidade que luz transmitida através dos protetores oculares quando usado o HP-3M ESPE foi significantemente maior quando comparado aos valores para o Valo, independentemente do filtro testado. Quando foi utilizado a fonte de luz HP-3M ESPE, o filtro de proteção ocular permitiu significativamente maior passagem de luz, seguido por XL 3000, ORTUS, Google Professional, e pelo filtro Gnatus. O filtro do Valo foi o mais eficiente ao bloquear a luz prejudicial. Alguns filtros foram menos eficazes ao bloquear menores comprimentos de onde (<420 nm). No entanto, mesmo no pior cenário dos resultados deste estudo, os filtros foram capazes de bloquear ao menos 97% da irradiância emitida pelas fontes de luz testadas.


Subject(s)
Humans , Curing Lights, Dental/adverse effects , Eye Protective Devices/standards , Analysis of Variance , Optics and Photonics
8.
Journal of China Medical University ; (12): 385-387, 2017.
Article in Chinese | WPRIM | ID: wpr-616147

ABSTRACT

Objective To explore the difference in ocular biologically effective ultraviolet irradiance in two areas with different altitudes ,Xichang and Shaoxing,and provide a reference basis for ocular UV protection. Methods A self?designed rotating mannequin and dual?detector spectrome?ter were used to monitor the intensity of ocular exposure to UV irradiation under clear skies in Xichang and Shaoxing. Monitoring data were pro?cessed and analyzed with AvaSoft 7.4 USB2 software and OriginPro 8.0 software. Results The diurnal variations of ocular biologically effective ul?traviolet irradiance exhibited bimodal distribution in Xichang and Shaoxing. The maximum UVBEcorn,UVBEconj,and UVBElens of Xichang were about 1.7 times,2 times,and 1.8 times that of Shaoxing,respectively. Under the same solar elevation angle,the biologically effective ultraviolet irra?diance of the cornea,conjunctiva,and lens in Xichang were higher than those of Shaoxing. Conclusion The diurnal variations of ocular biologi?cally effective ultraviolet irradiance exhibit bimodal distribution in areas at two different altitudes. Under the same solar elevation angle ,the biologi?cally effective ultraviolet irradiance of the cornea,conjunctiva,and lens of Xichang are significantly higher than those of Shaoxing.

9.
Military Medical Sciences ; (12): 594-597, 2017.
Article in Chinese | WPRIM | ID: wpr-661587

ABSTRACT

Objective To design a set of matrix solar radiation simulation ,that can be used to study the thermal comfort of armored vehicles.Methods With xenon lamps as the light source , the lifting matrix lamp array controlled by the computer was used to test the whole vehicles .Results The system could irradiate the top , the left and right sides of the armored vehicle, and the intensity of irradiation ranged from 200 to 1200 W/m2 in order to adapt to vehicles of different sizes and heights.Conclusion The system can meet the needs of solar simulation experiments of different armored vehicles.

10.
Military Medical Sciences ; (12): 594-597, 2017.
Article in Chinese | WPRIM | ID: wpr-658668

ABSTRACT

Objective To design a set of matrix solar radiation simulation ,that can be used to study the thermal comfort of armored vehicles.Methods With xenon lamps as the light source , the lifting matrix lamp array controlled by the computer was used to test the whole vehicles .Results The system could irradiate the top , the left and right sides of the armored vehicle, and the intensity of irradiation ranged from 200 to 1200 W/m2 in order to adapt to vehicles of different sizes and heights.Conclusion The system can meet the needs of solar simulation experiments of different armored vehicles.

11.
Rev. bras. farmacogn ; 24(5): 516-523, Sep-Oct/2014. tab, graf
Article in English | LILACS | ID: lil-730565

ABSTRACT

Light can act on essential oil yield directly on synthesis of secondary metabolites, or indirectly on plant growth. Varronia curassavica Jacq., Boraginaceae, is a native medicinal species from Brazil known as “erva-baleeira”, with anti-inflammatory activity related to its essential oil. Despite pharmacological evidences of this species and its economic importance for herbal medicine production, little is known about the effect of light on growth and essential oil production. This study aimed to analyze the influence of different irradiances on growth, frequency of trichomes, essential oil yield and composition of V. curassavica. The irradiance affected plant growth, but no significant alteration on leaf biomass was detected. The increase in essential oil content under higher irradiance reflected on essential oil yield, and is associated with higher frequency of glandular, globular trichomes. The essential oil composition, rich in caryophyllene derivatives was affected by irradiance, but α-humulene, the constituent of pharmaceutical interest, remained unchanged.

12.
Rev. bras. farmacogn ; 22(4): 818-824, jul.-ago. 2012. ilus
Article in English | LILACS | ID: lil-640357

ABSTRACT

The success of seaweed cultivation depends on the scientific control of the tolerance limits and the optimal physiological conditions that affect the spore germination and the early development of algal species. In order to establish cultivation techniques for spores of Hidropuntia caudata (J. Agardh) Gurgel & Fredericq, the effects of irradiance, salinity, and temperature on the carpospore germination and carposporeling development were evaluated under laboratory conditions. Five photon flux densities (PFD, from 18 to 200 µmol photons m-2s-1), six salinity values (from 7 to 55 psu), and four temperatures (from 20 ºC to 35 ºC) were investigated. The level of irradiance caused significant differences in the growth, in the following order: 200±5 > 100±5 ~= 62.5±2.5 > 30±1.5 > 18±1 µmol of photons m-2s-1, but they did not inhibit the carposporeling development. Maximum growth occurred under 35 psu, while at 15 psu the formation of carposporeling erect axis was limited. The optimal temperature for growth was 25 ºC, while at 35 ºC the spores died. These results show the importance of previous knowledge on the tolerance limits and optimal conditions for sporeling development of H. caudata for the implementation of an aquaculture program.

13.
Ciênc. rural ; 42(2): 276-282, fev. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-618112

ABSTRACT

A radiação solar é um dos elementos responsáveis pela manutenção da vida no planeta. Apesar da sua importância, o registro da radiação solar não é feito na maioria das estações meteorológicas convencionais, uma vez que nem todas dispõem de equipamentos para medi-la, tendo que recorrer a métodos de estimação empíricos. Com o intuito de testar e calibrar equações para estimar a radiação solar, foram coletados dados de quatro estações meteorológicas pertencentes ao Instituto Nacional de Meteorologia (INMET) para representar a região climática noroeste de Minas Gerais, no período de 2008 a 2010. Com base nesses dados, foram testados e calibrados nove modelos para estimar a radiação solar global. Todos os modelos utilizam temperatura máxima e mínima do ar como preditores e dois deles utilizam também a precipitação pluviométrica. Os modelos mais precisos foram de De Jong e Stewart, Bristow e Campbell, Donatelli e Campbell e o modelo dois de Hunt, com raiz quadrada do quadrado médio do erro em torno de 3,1MJ m-2 d-1 e coeficiente de determinação em torno de 62 por cento. No entanto, todos esses modelos apresentaram tendência de superestimação para valores de radiação inferiores à média e subestimação para valores superiores. Portanto, há necessidade de propor novos modelos que minimizem essa tendência.


Solar radiation is a component responsible for maintaining the life on the planet. Despite its importance, solar radiation is not recorded in most conventional meteorological station since not all have equipments to measure it, and then, it is usual to use empirical solar radiation estimation methods. In order to test and calibrate models for estimating solar radiation data were collected from four meteorological stations belonging to the National Institute of Meteorology (INMET) to represent the climatic region northwest of Minas Gerais for the period from 2008 to 2010. Based on these data, nine models to estimate global solar radiation were tested and calibrated. All the models use maximum and minimum air temperature as predictor and two of them also use rainfall. The most accurate models were De Jong and Stewart, Bristow and Campbell, Donatelli and Campbell and model of two Hunt, with root mean square error about 3.1MJ m-2 d-1 and determination coefficient around of 62 percent. However, all these models tended to have an overestimation for values of radiation below the average and an underestimation for values higher than the average. Therefore there is need to propose new models that minimize this trend.

14.
Article in English | IMSEAR | ID: sea-162560

ABSTRACT

Harmonic Analysis technique has been employed in predicting the hourly air temperature variations over Lagos and Abuja, Nigeria. The variations in hourly air temperatures over the two stations are periodic and thus have strong tendency of being repeated the next day, if all other atmospheric variables are constant. It was observed that the variation in hourly air temperature in the two stations is dominated by the first harmonic, thus it fluctuates by one cycle with a period of 24 hours. Invariably, harmonic equations could be applied to hourly temperature prediction even on a large scale data. The maximum hourly air temperature occurred two hours on the average after the maximum solar irradiance has occurred in each station. It was found that the temperature of the air at a particular hour is dependent on that of the previous hour.

15.
Biol. Res ; 43(1): 127-135, 2010. graf
Article in English | LILACS | ID: lil-548036

ABSTRACT

Plant cell cultures could be used as an important tool for biochemical production, ranging from natural coloring (pigments) to pharmaceutical products. Anthocyanins are becoming a very important alternative to synthetic dyes because of increased public concern over the safety of artificial food coloring agents. Several factors are responsible for the production of anthocynin in cell cultures. In the present study, we investigate the effects of different environmental factors, such as light intensity, irradiance (continuous irradiance or continuous darkness), temperature and medium pH on cell biomass yield and anthocyanin production in cultures of Melastoma malabathricum. Moderate light intensity (301 - 600 lux) induced higher accumulation of anthocyanins in the cells. The cultures exposed to 10-d continuous darkness showed the lowest pigment content, while the cultures exposed to 10-d continuous irradiance showed the highest pigment content. The cell cultures incubated at a lower temperature range (20 ± 2 ºC) grew better and had higher pigment content than those grown at 26 ± 2ºC and 29 ± 2ºC. Different medium pH did not affect the yield of cell biomass but anthocyanin accumulation was highest at pH 5.25 - 6.25.


Subject(s)
Anthocyanins/biosynthesis , Biomass , Melastomataceae/cytology , Cell Culture Techniques , Light , Melastomataceae/metabolism , Stress, Physiological
16.
Rev. biol. trop ; 56(2): 421-429, jun. 2008. graf, tab
Article in Spanish | LILACS | ID: lil-637648

ABSTRACT

Growth and metabolite production of the marine cyanobacterium Synechococcus sp. (Chroococcales) in function to irradiance. Changes in salinity, temperature and irradiance during wet and dry seasons have induced metabolic versatility in cyanobacteria from saline environments. Cyanobacteria from these environments have biotechnological potential for the production of metabolites with pharmaceutical and industrial interest. We studied the growth, dry mass and metabolite production of the cyanobacterium Synechococcus sp. MOF-03 in function of irradiance (78, 156 and 234 µmol q m-2 s-1). All batch cultures were maintained by triplicate in constant aeration, 12:12 h photoperiod, 30 ±2ºC and 35‰. Maximum values of protein, carbohydrates and lipids, of 530.19 ±11.16, 408.94 ±4.27 and 56.20 ±1.17 µg ml-1, respectively, were achieved at 78 µmol q m-2 s-1. Pigments, analyzed by HPLC, showed maximum values at 78 µmol q m-2 s-1 for chlorophyll a with 7.72 ±0.16 µg ml-1, and at 234 µmol q m-2 s-1 for ß-carotene and zeaxanthin with 0.70 ±0.01 and 0.67 ±0.05 µg ml-1. Chlorophyll a:ß-carotene ratio decreased from 17.15 to 6.91 at 78 and 234 µmol q m-2 s-1; whereas ß-carotene:zeaxanthin ratio showed no changes between 78 and 156 µmol q m-2 s-1, around 1.21, and decreased at 234 µmol q m-2 s-1, to 1.04. Also, this cyanobacterium produced the greatest cell density and dry mass at 156 µmol q m-2 s-1, with 406.13 ±21.74 x106 cell ml-1 and 1.49 ±0.11 mg ml-1, respectively. Exopolysaccharide production was stable between 156 y 234 µmol q m-2 s-1, around 110 µg ml-1. This Synechococcus strain shows a great potential for the production of enriched biomass with high commercial value metabolites. Rev. Biol. Trop. 56 (2): 421-429. Epub 2008 June 30.


Las cianobacterias de ambientes salinos presentan una versatilidad metabólica inducida por los cambios de salinidad, temperatura e irradiancia, durante los períodos de sequía y lluvias. Por ello es importante la búsqueda en estos ambientes de cianobacterias con potencial biotecnológico para la producción de metabolitos de interés farmacéutico e industrial. Se reporta el crecimiento, masa seca y producción de metabolitos de la cianobacteria Synechococcus sp. MOF-03 en función de la irradiancia (78, 156 y 234 µmol q m-2 s-1). Los cultivos discontinuos por triplicado, fueron mantenidos con aireación constante, fotoperiodo 12:12 h, 30 ±2ºC y a 35‰. Los máximos valores de proteínas, carbohidratos y lípidos de 530.19 ±11.16, 408.94 ±4.27 y 56.20 ±1.17 µg ml-1 respectivamente, fueron obtenidos a 78 µmol q m-2 s-1. Los pigmentos, analizados por HPLC, mostraron los máximos a 78 µmol q m-2 s-1 para clorofila a con 7.72 ±0.16 µg ml-1; y a 234 µmol q m-2 s-1 para ß-caroteno y zeaxantina con 0.70 ±0.01 and 0.67 ±0.05 µg ml-1. La relación clorofila a:ß-caroteno disminuyó de 17.15 hasta 6.91 a 78 y 234 µmol q m-2 s-1; mientras que la relación ß-caroteno:zeaxantina se mantuvo sin cambios entre 78 y 156 µmol q m-2 s-1, con cerca de 1.21 y disminuyó a 234 µmol q m-2 s-1 a 1.04. La cianobacteria produjo la mayor densidad celular y masa seca a 156 µmol q m-2 s-1, con 406.13 ±21.74 x106 cel ml-1 y 1.49 ±0.11 mg ml-1 respectivamente. La producción de exopolisacáridos se mantuvo alrededor de 110 µg ml-1 entre 156 y 234 µmol q m-2 s-1. Así, esta cepa de Synechococcus muestra un gran potencial para la producción de biomasa enriquecida con metabolitos de alto valor comercial.


Subject(s)
Chlorophyll/biosynthesis , Synechococcus/radiation effects , Xanthophylls/biosynthesis , beta Carotene/biosynthesis , Chromatography, High Pressure Liquid , Photoperiod , Synechococcus/growth & development , Synechococcus/metabolism , Temperature , Ultraviolet Rays
17.
Braz. dent. j ; 19(3): 197-203, 2008. graf, tab, ilus
Article in English | LILACS | ID: lil-495972

ABSTRACT

This study evaluated the irradiance of curing units through core and veneered hot-pressed ceramics as well as the transmittance of these materials. Discs of 0.7, 1.4 and 2 mm in thickness of Empress (EMP) and Empress Esthetic (EST), and 0.8 (n=5) and 1.1 mm (n=5) thickness of Empress 2 (E2) were obtained. For E2, two of the 0.8-mm-thick discs were covered with dentin (1.2- and 1.4-mm-thick) and two with dentin + enamel (1.5-mm-thick). The 1.1-mm-thick specimens were submitted to the same veneering procedures. Specimens were evaluated by UV-Vis transmittance analysis and the percentage of transmittance was recorded. Irradiance through each specimen was evaluated with a quartz-tungsten-halogen (QTH), used in continuous or intermittent exposure modes, or a blue light-emitting diode (LED). Data were analyzed by Dunnett's test, ANOVA and Tukey's test at 5 percent significance level. Exposure through ceramic decreased the irradiance for all ceramics. Irradiance through EST was significantly higher than through EMP. For E2, reduction in irradiance depended on the core and/or veneer thickness. The QTH intermittent mode showed higher irradiance than the continuous mode, and both showed higher irradiance than LED. The ceramic significantly influenced irradiance and transmittance, which were found to decrease with the increase in thickness.


Este estudo avaliou a irradiância de unidades de fotoativação através de cerâmicas para subestrutura com e sem cobertura, e a transmitância desses materiais. Discos de 0,7, 1,4 e 2 mm de espessura de Empress (EMP) e Empress Esthetic (EST), e de 0,8 (n=5) e 1,1 mm (n=5) de espessura de Empress 2 (E2) foram obtidos. Para E2, dois discos de 0,8 mm foram cobertos com dentina (1,2 e 1,4 mm de espessura) e dois com dentina + esmalte (1,5 mm de espessura). Os discos de 1,1 mm de espessura foram submetidos aos mesmos procedimentos de cobertura. Os espécimes foram avaliados por análise de transmitância UV-Vis e o percentual de transmitância foi registrado. A irradiância através dos discos foi avaliada com fonte de luz de lâmpada halógena de quartzo-tungstênio (QTH), utilizada nos modos contínuo ou intermitente, e diodo emissor de luz (LED). Os dados foram analisados com testes de Dunnett, ANOVA e Tukey com nível de significância de 5 por cento. A exposição através da cerâmica reduziu a irradiância para todas as cerâmicas. A irradiância através de EST foi maior que EMP. Para E2, a redução dependeu da espessura da subestrutura e/ou cobertura. O modo intermitente para QTH mostrou maior irradiância que o modo contínuo; ambos apresentaram maior irradiância que o LED. A cerâmica influenciou significativamente a irradiância e transmitância, que diminuíram com o aumento da espessura.


Subject(s)
Humans , Aluminum Silicates/chemistry , Dental Materials/chemistry , Dental Porcelain/chemistry , Aluminum Silicates/radiation effects , Color , Curing Lights, Dental , Dental Veneers , Dental Materials/radiation effects , Dental Porcelain/radiation effects , Glass/chemistry , Glass/radiation effects , Hot Temperature , Light , Lithium Compounds/chemistry , Lithium Compounds/radiation effects , Materials Testing , Photochemical Processes , Spectrophotometry , Spectrophotometry, Ultraviolet , Surface Properties
18.
Journal of Korean Academy of Conservative Dentistry ; : 213-223, 2008.
Article in English | WPRIM | ID: wpr-77635

ABSTRACT

The objective of this study was to compare dentin shear bond strength (DSBS) of dentin bonding agents (DBAs) cured with a plasma arc (PAC) light curing unit (LCU) and those cured with a light emitting diode (LED) LCU. Optical properties were also analyzed for Elipar freelight 2 (3M ESPE); LED LCU, Apollo 95E (DMT Systems); PAC LCU and VIP Junior (Bisco); Halogen LCU. The DBAs used for DSBS test were Scotchbond Multipurpose (3M ESPE), Singlebond 2 (3M ESPE) and Clearfil SE Bond (Kuraray). After DSBS testing, fractured specimens were analyzed for failure modes with SEM. The total irradiance and irradiance between 450 nm and 490 nm of the LCUs were different. LED LCU showed narrow spectral distribution around its peak at 462 nm whereas PAC and Halogen LCU showed a broad spectrum. There were no significant differences in mean shear bond strength among different LCUs (P > 0.05) but were significant differences among different DBAs (P < 0.001).


Subject(s)
Dentin , Dentin-Bonding Agents , Enzyme Multiplied Immunoassay Technique , Light , Plasma , Resin Cements
19.
Braz. j. biol ; 64(3)2004.
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1467745

ABSTRACT

Irradiance is a crucial factor in plant development. Different radiant energy levels cause different responses related to plant growth and the production and distribution of dry matter. Considering the relationship between light availability and metabolism of carbohydrates and derived compounds, the aim of this work was to assess the effects of irradiance on non-structural carbohydrate contents and composition, as well as on the hypoglycemiant activity of Rhynchelytrum repens, a pantropical grass species popularly used for diabetes treatment. Plants of R. repens growing under natural irradiance (NI) showed increased content of total soluble carbohydrate (TSC), higher fluctuations in starch content (SC) and higher number of tillers. The flowering process of these plants was preceded by an increase in sucrose. However, their water content was low when compared to that of plants cultivated under low irradiance (LI). The ratio root/aerial organs and SC showed no significant differences in plants grown under LI, although TSC increased and a lower number of tillers were observed during the experimental period. In both conditions, sucrose was the ubiquitous sugar and seemed to be involved in the flowering process. A reduction in the blood sugar level was observed through the intra-peritoneal (IP) administration of the precipitate of aqueous extracts obtained from plants growing in both conditions of light; the supernatant fraction showed no hypoglycemic effect.


A irradiância é um fator crucial em reações vitais para o crescimento e desenvolvimento das plantas. A utilização da energia radiante pelos vegetais afeta diferentes respostas em relação ao padrão de desenvolvimento e à produção de matéria seca e sua conseqüente distribuição. Tendo em vista a intrínseca relação entre disponibilidade de luz, acúmulo de biomassa e metabolismo de carboidratos e compostos relacionados, os objetivos deste trabalho foram avaliar o efeito da irradiância sobre o conteúdo e a composição dos carboidratos não-estruturais, sobre o desenvolvimento e sobre a atividade hipoglicemiante de Rhynchelytrum repens, uma gramínea pantropical de origem africana utilizada popularmente no tratamento de diabetes. O cultivo a pleno sol (PS) estimulou aumento no conteúdo de carboidratos solúveis totais (CST), no perfilhamento das plantas e nas flutuações do conteúdo de amido (CA). O florescimento dessas plantas foi precedido por um aumento de CST, especialmente de sacarose. Foi observado também menor conteúdo de água nas plantas sob PS quando comparado com as plantas cultivadas sob irradiância reduzida (IR). Nesta última condição, o CA e a razão raiz/parte aérea não sofreram alterações significativas, porém houve aumento no conteúdo de CST ao longo do período experimental, menor grau de perfilhamento e formação de raízes adventícias aéreas. Em ambas as condições de luminosidade, a sacarose foi o açúcar mais abundante e com maiores variações. Esse açúcar parece estar envolvido nos processos de florescimento da espécie. Uma redução no nível de glicose plasmática foi observada a partir da administração do precipitado do extrato aquoso de R. repens obtido de plantas cultivadas em PS e IR, não havendo diferença significativa entre os tratamentos. A fração sobrenadante não apresentou efeito hipoglicemiante.

20.
Article in English | IMSEAR | ID: sea-137692

ABSTRACT

The Siriraj Phototherapy Lamp (SPL) was invented by the investigator to compensate for a similar, but expensive imported device and h low-efficiency locally-made device. The SPL irradiance and effect on environmental temperature were measured in this study. The device used six fluorescent bulbs of which zero to three were blue. The distance between the bulbs and the mattress was fully adjustable. The blue fluorescent bulb emitted a higher light intensity than the white. In both kinds of bulbs the intensity of light was higher in the center of the bulbs than at the periphery. The light intensity varied proportionately with the number of blue fluorescent bulbs, but inversely with the distance between the bulbs and the mattress. Lining the SPL with a white cloth increased the light intensity. This inverse relationship was also found between the environmental temperature near the mattress and the distance. Placing a plastic shield under the SPL reduced the radiant heat emitted by the bulbs to the mattress which resulted in a decrease of environmental temperatures by 2.3oC and 3.0oC at the distances of 45 and 30 cm, respectively.

SELECTION OF CITATIONS
SEARCH DETAIL